Air Conditioning & Ventilation

Air conditioning is the system nobody thinks about until it fails, and then it fails visibly: a brown stain spreading across a new gypsum ceiling, a bedroom that never gets cold because the unit was chosen from a catalogue, an outdoor condenser eaten through by three seasons of salt. We size it against the actual house, route it before the ceilings close, drain it properly and commission it with the numbers written down.

We sourceWe manufactureWe install

Scope of works

What we actually do.

Everything below happens inside our business — no subcontracted links in the chain.

  1. 01

    Split & multi-split systems

    Wall and floor-standing units for apartments and room-by-room control, with pipe runs planned into walls and risers instead of stapled across a façade after the paint is finished.

  2. 02

    VRF / VRV systems

    One outdoor unit serving many indoor units with individual control — the sensible answer for a villa across three floors where you do not want a condenser garden on the roof and a meter running for empty rooms.

  3. 03

    Ducted & concealed units

    Concealed units in ceiling voids feeding linear or square grilles, with duct routes coordinated with the gypsum ceilings, lighting and structure so the ceiling does not drop 40 cm to hide a mistake, and access hatches at every unit.

  4. 04

    Chilled water for larger buildings

    Chillers, pumps, insulated pipework and fan coils where the load is beyond a sensible refrigerant system — larger villas, buildings and commercial premises — with plant located and acoustically treated rather than dumped on the nearest roof.

  5. 05

    Ventilation, drainage & commissioning

    Fresh air supply, kitchen and bathroom extraction ducted to outside, insulated condensate drains laid to fall and run to a real outlet, then commissioning: airflow, temperature split, drain test and refrigerant charge recorded and handed over.

Specification

The numbers, before you ask.

Air Conditioning & Ventilation — technical specification
SystemsSplit · multi-split · VRF/VRV · ducted concealed · chilled water
CondensateInsulated drain lines, minimum 1:100 fall, run to a proper outlet — never a void
Refrigerant pipeInsulated copper, pressure tested and vacuumed before charging
Coastal specificationAnti-corrosion coated coils and stainless fixings within reach of sea air
VentilationKitchen and bathroom extraction ducted outside, not into a ceiling void
CommissioningAirflow, temperature split, drain test and charge recorded at handover
Two Carrier condensers bracketed to the wall, drain and conduit run
Two Carrier condensers bracketed to the wall, drain and conduit run

Selection

What suits which house

  • Apartment, splitsCairo & Alexandria

    Room-by-room units, tidy pipe routes and a condensate line that reaches a drain. Simple, cheap to service, easy to replace one unit without touching the rest.

  • Villa, ducted & concealedNew Cairo & Zayed

    Concealed units and grilles for reception and bedrooms where nobody wants a box on the wall. Requires ceiling coordination from the first drawing, not from the day the ceiling goes up.

  • Villa, VRFMultiple floors

    One outdoor unit, many indoor units, individual control and part-load efficiency. The right answer when half the house is empty half the time.

  • Chilled water & roof plantLarge properties

    For loads beyond refrigerant systems, with plant, pumps and insulated distribution designed together and acoustics considered before a neighbour complains.

  • Sahel chaletNorth Coast

    For chalets in Marassi, Hacienda Bay, Almaza Bay and Fouka Bay: coated coils, stainless fixings, shaded and raised condensers, a documented shut-down routine for the winter and a service before the season opens.

  • Retrofit into a finished houseExisting homes

    Routes taken through wardrobes, cupboards and small false beams, with honest advice about the chasing and making good that cannot be avoided.

Gallery

Air Conditioning & Ventilation in place.

Every photograph on this page was taken on one of our sites during the work. Nothing here is a stock image or a render.

Two Carrier condensers stacked on wall brackets, refrigerant pipework insulated, isolators and conduit down the wall
Two Carrier condensers stacked on wall brackets, refrigerant pipework insulated, isolators and conduit down the wall
Pressure gauge connected to the AC unit during gas charging
Pressure gauge connected to the AC unit during gas charging
Wall-mounted split head installed and running in a finished room
Wall-mounted split head installed and running in a finished room

Where it goes

  • Villas & duplexes
  • Apartments & penthouses
  • North Coast chalets
  • Home cinemas & gyms
  • Kitchen & bathroom extraction
  • Laundry & plant rooms
  • Shops, cafés & clinics

Questions we get asked

Air Conditioning & Ventilation — questions we get asked

Why does my air conditioning drip and stain the ceiling?
Almost always the condensate, not the unit. The drain was laid flat or backfalling, it was run into a ceiling void instead of an outlet, the pipe was not insulated so it sweats along its whole length in an Egyptian summer, or the trap dried out and the unit pulled water back. We lay drains to a measured fall, insulate them, terminate them somewhere real, and flood test before the ceiling is closed.
Split, VRF or ducted for a villa?
Splits are cheapest to install and to fix, but you see them and you run a condenser for every room. Ducted concealed units are invisible and quiet, and need the ceiling coordinated from the start. VRF costs more up front and earns it back in a house where rooms are used unevenly, because it modulates instead of switching whole units on and off. In most villas we mix them: VRF or ducted through the main floors, a simple split in the staff room and the gym.
My chalet is closed nine months a year. What does that change?
Everything about the specification. Idle equipment in sea air corrodes faster than working equipment in Cairo, so condensers get coated coils, stainless fixings, a raised and shaded position, and a rinse-down before shutdown. We leave you a written closing routine — isolate, drain, cover the right things and not the wrong ones — and we service before the season rather than in the first hot weekend when every engineer in Sahel is already booked.
How do you size a house that is only used for one hot weekend?
On pull-down, not on steady state. A closed house that has been baking for weeks needs capacity to drag the whole structure down on a Thursday night, which is a different calculation from holding a temperature in an occupied villa. That said, oversizing is its own failure: an oversized unit short-cycles, never runs long enough to dehumidify, and leaves a room that is cold and clammy at the same time. We calculate the load and tell you where we landed and why.
Can you install air conditioning in an already finished house?
Yes, and we will be straight with you about the disruption. Routes go through wardrobes, cupboards, small false beams and existing risers wherever possible, and where a wall must be chased we agree it and make it good, including the paint. What we will not do is hide a pipe run behind a decorative box and call it a design feature.

Written quotation

Tell us about the job. We reply with a written quotation.

Name and phone are enough to start. We call you back, ask the questions that matter, and you get an itemised quotation in writing — no figures guessed over the phone.

  • You pay the supplier directly, and the tax invoice is in your name.
  • Finishing, decoration and supply from one company.
  • Every photo on this site is our own work.

Or reach us directly

Please write your name.
Please write a phone number we can call.

We use your number only to answer this enquiry.

WhatsApp